XTV Self-Regulating Heating Cable - nVent Raychem

Maintains Temperatures up to 121°C

XTVR-Self-Regulating-Heat-Tracing-Cable-nVent-Raychem
PDF
The nVent RAYCHEM XTV self-regulating trace heating cable is engineered for freeze protection of pipes and vessels requiring steam cleaning, along with process temperature maintenance, operating efficiently up to 250°F/121°C. T

XTV Self-Regulating Heating Cable - Raychem

Maintains Temperatures up to 121°C

XTVR-Self-Regulating-Heat-Tracing-Cable-nVent-Raychem
PDF

The RAYCHEM XTV self-regulating trace heating cable is engineered for freeze protection of pipes and vessels requiring steam cleaning, along with process temperature maintenance, operating efficiently up to 250°F/121°C. These cables withstand intermittent exposure to 482°F/250°C and feature a fluoropolymer outer jacket (-CT) for exceptional resistance against aggressive organics and corrosives.

Specifically designed for freeze protection and maintaining process temperatures in pipes and vessels demanding high power output and exposure temperatures, the XTVR heating cables endure temperatures up to 482°F (250°C) while offering process temperature maintenance up to 302°F (150°C). Incorporating a high power retention (HPR) heating core, these cables ensure highly reliable power output for extended operational life.

Raychem XTV Heating Cable Features

  • Simplified design for hazardous areas: T2 and T3-T6 based on systems approach.
  • Longer circuit lengths due to larger cross-section conductors.
  • Swift installation: cut-to-length capability, multiple overlaps allowed, meter markings, user-friendly connection kits.
  • Safe and efficient operation: prevents overheating, maintains uniform pipe temperatures, incorporates energy-saving technology

Raychem XTV Heating Cable Specifications

  • Supply Voltage: 200 – 277 V
  • Max. Continuous Exposure Temperature: 121 °C
  • Max. Intermittent Exposure Temperature: 250 °C
  • Max Cumulative Hours for Intermittent Exposure: 1000 h
  • Ground Path Type: Braid
  • Area Classification: Non-Hazardous & Hazardous
  • Outer Jacket Material: High Temperature Fluoropolymer

Related Raychem Products

hese cables withstand intermittent exposure to 482°F/250°C and feature a fluoropolymer outer jacket (-CT) for exceptional resistance against aggressive organics and corrosives.

Specifically designed for freeze protection and maintaining process temperatures in pipes and vessels demanding high power output and exposure temperatures, the XTVR heating cables endure temperatures up to 482°F (250°C) while offering process temperature maintenance up to 302°F (150°C). Incorporating a high power retention (HPR) heating core, these cables ensure highly reliable power output for extended operational life.[/vc_column_text]

nVent Raychem XTV Heating Cable Features

  • Simplified design for hazardous areas: T2 and T3-T6 based on systems approach.
  • Longer circuit lengths due to larger cross-section conductors.
  • Swift installation: cut-to-length capability, multiple overlaps allowed, meter markings, user-friendly connection kits.
  • Safe and efficient operation: prevents overheating, maintains uniform pipe temperatures, incorporates energy-saving technology

nVent Raychem XTV Heating Cable Specifications

  • Supply Voltage: 200 – 277 V
  • Max. Continuous Exposure Temperature: 121 °C
  • Max. Intermittent Exposure Temperature: 250 °C
  • Max Cumulative Hours for Intermittent Exposure: 1000 h
  • Ground Path Type: Braid
  • Area Classification: Non-Hazardous & Hazardous
  • Outer Jacket Material: High Temperature Fluoropolymer