HTEK Constant-Watt Industrial Heating Cable - Thermon

Temperature Maintenance: up to 204⁰C

Thermon HTEK-Series-Constant-Watt-Heating-Cable
PDF

The Thermon HTEK Constant-Watt Industrial Heating Cable represents a high-performance solution specifically designed for long line temperature maintenance or freeze protection in applications where circuit lengths surpass the limitations of parallel resistance heating cables. Ideal for scenarios demanding high maintain temperatures or exposure to elevated temperatures, HTEK stands out as a reliable and efficient choice.

Notably, HTEK is engineered to handle circuit lengths of up to 3,658 meters (12,000 feet), making it exceptionally suitable for extended installations. This extended reach can be energized from a single power supply point, enhancing efficiency and simplifying the overall system configuration.

The series circuitry of HTEK ensures consistent power output along the entire length of the cable, eliminating concerns related to voltage drops often associated with parallel tracer constructions. This feature contributes to the reliability and uniformity of heat distribution, critical for applications where maintaining a consistent temperature is paramount.

HTEK cables are approved for use in both ordinary (non-classified) and hazardous (classified) areas, underscoring their versatility and reliability across a spectrum of industrial environments. This approval provides peace of mind regarding the safety and compliance of the cable in various settings.

In summary, the HTEK Constant-Watt Industrial Heating Cable is a high-performance solution tailored for demanding applications requiring long line temperature maintenance or freeze protection. With its ability to handle extended circuit lengths, consistent power output, and approval for use in both ordinary and hazardous areas, HTEK stands as a dependable choice for industries where maintaining precise temperatures is essential.

HTEK Industrial Heating Cable Construction

  1. Heating conductors (2 or 3)
  2. Fluoropolymer dielectric Insulation over fiberglass composite
  3. Fluoropolymer pairing jacket
  4. Nickel-plated copper braid
  5. Fluoropolymer over jacket provides additional protection for cable and braid where exposure to chemicals or corrosives is expected.

HTEK Industrial Heating Cable Specifications

  • Rated voltage for operation: up to 600 Vac
  • Max. maintenance temperature: 400°F (204°C)
  • Max. continuous exposure temperature: Power-off 500°F (260°C)
  • Minimum installation temperature: -60°F (-51°C)
  • Minimum bend radius:
    @ 5°F (-15°C) 0.875” (22mm)
    @ -76°F (-60°C) 1.25” (32 mm)